Ядерна фізика та енергетика
ISSN:
1818-331X (Print), 2074-0565 (Online) |
Home page | About |
Analysis of uncertainties of gamma-ray energy measurement made with semiconductor spectrometers
A. P. Lashko, T. N. Lashko
Institute for Nuclear Research, National Academy of Sciences of Ukraine, Kyiv, Ukraine
Abstract: Detailed analysis of all possible experimental uncertainties accompanying γ-ray energy measurements completed with semiconductor spectrometers has been performed. Recommendations are given concerning minimizing such uncertainties, the most optimal procedures for making such investigations are suggested.
References:1. Borchert G. L., Scheck W., Schult Q. W. B. Curved crystal spectrometer for precise energy measurement of gamma-rays from 30 to 1500 keV. Nucl. Instrum. and Methods 124 (1975) 107. https://doi.org/10.1016/0029-554X(75)90391-2
2. Matsui S., Inoue H., Yoshizawa Y. Gamma-ray energy measurement for 177mLu with a precision pulser. Nucl. Instrum. Meth. Phys. Res. A 281 (1989) 568. https://doi.org/10.1016/0168-9002(89)91491-5
3. Helmer R. G., Reich C. W. An excited state of 229Th at 3.5 eV. Phys. Rev. C 49 (1994) 1845. https://doi.org/10.1103/PhysRevC.49.1845
4. Джелепов Б. С., Шестопалова С. А. Ядерно-спектроскопические нормали (Москва: Атомиздат, 1980) 232 с.
5. Helmer R. G., Van der Leun C. Recommended standards for γ-ray energy calibration. Nucl. Instrum. Meth. Phys. Res. A 422 (1999) 525. https://doi.org/10.1016/S0168-9002(98)01079-1
6. Helmer R. G., Van der Leun C. Recommended standards for γ-ray energy calibration (1999). Nucl. Instrum. Meth. Phys. Res. A 450 (2000) 35. https://doi.org/10.1016/S0168-9002(00)00252-7
7. Купряшкин В. Т., Лашко А. П., Лашко Т. Н., Феоктистов А. И. Энергии гамма-переходов и уровней 181Та в распаде 181Hf. Изв. РАН. Сер. физ. 69 (2005) 637.
8. Хоменков В. П. Дослідження атомно-ядерних ефектів у процесі внутрішньої конверсії гамма-променів: Автореф. дис. ... канд. фіз.-мат. наук. ІЯД НАН України (Київ, 2003) 19 с.
9. Булгаков В. В., Гаврилюк В. И., Лашко А. П. и др. Магнитный бета-спектрометр высокого разрешения ИЯИ АН УССР. Препр. АН УССР. Ин-т ядерных исслед. КИЯИ-86-33 (Київ, 1986) 48 с.
10. Лашко А. П., Лашко Т. Н., Одинцов А. А., Хоменков В. П. Комплексный анализ изотопного состава плутония в аварийном выбросе 4-го энергоблока Чернобыльской АЭС. Атомная энергия 91 (2001) 443.
11. Sakai E. Charge Collection in Coaxial Ge(Li) Detectors. IEEE Trans. Nucl. Sci. 15 (1968) 310. https://doi.org/10.1109/TNS.1968.4324952
12. Gunnink R., Meyer R. A., Niday J. B., Anderson R. P. Precise determinations of high-energy gamma rays and errors in the pair-peak method. Nucl. Instrum. and Methods 65 (1968) 26. https://doi.org/10.1016/0029-554X(68)90004-9
13. Helmer R. G., Gehrke R. J., Greenwood R. C. Peak position variation with source geometry in Ge(Li) detector spectra. Nucl. Instrum. and Methods 123 (1975) 51. https://doi.org/10.1016/0029-554X(75)90077-4
14. Джелепов Б. С. Методы разработки сложных схем распада (Наука, 1974) 232 с.
15. Казновецкий А. Б. и др. К вопросу точности определения энергии гамма-квантов с помощью HPGe-детектора. Точные измерения в ядерн. спектр.: Материалы Х Междунар. семинара по точн. измер. в ядерн. спектр. (ТИЯС Х), Валдай, 15 - 17 июня 1994 г. (СПб., 1994) c. 23.
16. Gruber U., Koch R., Maier B. P., Schult Q. W. B. Energie- und intensitat-messung der wahrend des 182Ta und 183Ta zerfalls von 182W und 183W ausgesandten γ-strahlung. Zeitschrift für Naturforschung A 20 (1965) 929. https://doi.org/10.1515/zna-1965-0709
17. Piller O., Beer W., Kern J. Das fokussierende kristall spectrometer der Universität Fribourg. Nucl. Instrum. and Methods 107 (1973) 61. https://doi.org/10.1016/0029-554X(73)90013-X