Selection of detector to optimize the exposure dose delivered to the patient during the radiography examination
L. I. Aslamova1, N. V. Melenevska1, I. V. Kulich1, N. S. Miroshnichenko1,2, S. I. Miroshnichenko2
1Taras Shevchenko National University, Educational and Scientific Center for Radiation Safety, Kyiv, Ukraine
2Production-Research Association "Teleoptic", Kyiv, Ukraine
Abstract: The aim of the research was to find the approach to optimize the exposure dose delivered to the patient during the annual fluorography chest organs examination, considering the needs to perform a large amount of procedures for population. The comparative analysis of gadolinium, improved gadolinium and cesium iodide was performed. The improved gadolinium screens combined with the next software X-ray test-object image processing are proposed for such X-ray diagnostic procedures.
Keywords: fluorography, x-ray detector, exposure dose.
References:1. Stadnyk L. L. Zb. Nauk. prats' Tret'ogo Mizhnar. Seminaru "Medychna Fizyka - Suchasnyj Stan, Problemy, Shlyakhy Rozvytku. Novitni Tekhnologiyi”. (Kyiv: TOV "SPT 'Bavok'", 2013) p. 19 (Ukr).
2. Farman T. T, Vandre R. H., Pajak J. C. et al. Effects of scintillator on the detective quantum efficiency (DQE) of a digital imaging system. Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology, and Endodontology 101 (2006) 219. https://doi.org/10.1016/S1079-2104(05)01189-3
3. Acciavatti R. J., Maidmenta A. D. A. A comparative analysis of OTF, NPS, and DQE in energy integrating and photon counting digital x-ray detectors. Medical Physics 37 (2010) 6480. https://doi.org/10.1118/1.3505014
4. Kandarakis I., Cavouras D., Prassopoulos P. et al. Evaluating scintillators used in radiation detectors of medical imaging systems by the effective fidelity index method. European J. of Radiology 30 (1999) 61. https://doi.org/10.1016/S0720-048X(98)00109-0
5. Cowen A. R., Davies A. G., Sivananthan M.U. The design and imaging characteristics of dynamic, solid-state, flat-panel x-ray image detectors for digital fluoroscopy and fluorography. Clinical Radiology 63 (2008) 1073. https://doi.org/10.1016/j.crad.2008.06.002
6. Samei E. Image quality in two phosphor-based flat panel digital radiographic detectors. Medical Physics 30 (2003) 1747. https://doi.org/10.1118/1.1578772
7. AAMP Report No. 31. Standardized methods for measuring diagnostics X-ray exposures, Report of task group 8 diagnostic X-ray imaging committee. (New York: The American Institute of Physics, 1990) p. 5.