Nuclear Physics and Atomic Energy

Ядерна фізика та енергетика
Nuclear Physics and Atomic Energy

  ISSN: 1818-331X (Print), 2074-0565 (Online)
  Publisher: Institute for Nuclear Research of the National Academy of Sciences of Ukraine
  Languages: Ukrainian, English
  Periodicity: 4 times per year

  Open access peer reviewed journal


 Home page   About 
Nucl. Phys. At. Energy 2001, volume 2, issue 3, pages 105-111.
Section: Radiation Physics.
Received: 16.02.2001; Published online: 30.09.2001.
PDF Full text (ua)
https://doi.org/10.15407/jnpae2001.03.105

Accuracy of coordinate determination of high-energy charged particles by silicon strip detectors

I. E. Anokhin, O. S. Zinets

Institute for Nuclear Research of the National Academy of Sciences of Ukraine, Kyiv, Ukraine

Abstract: The coordinate determination accuracy of minimum ionizing and short-range particles by silicon strip detector has been considered. The charge collection on neighboring strips of detector is studied and the influence of diffusion and the electric field distribution on accuracy are analyzed. It has been shown that coordinates of both minimum ionizing and short-range particles can be determined with an accuracy to a few microns using silicon strip detectors.

References:

1. Arnold L., Baudot J., Coffin J. P. et al. In-beam test of double-sided silicon strip detector. ALICE/SIL 98-05 Internal Note-SIL (22 January 1998).

2. Bosio C., Chochula P., Cindo V. et al. Test of a compact Si-strip detector for the forward region in DELPHI. Nuclear Instruments and Methods A 360 (1995) 71. https://doi.org/10.1016/0168-9002(95)00085-2

3. Belau E., Klanner R., Lutz G. et al. Charge collection in silicon strip detectors. Nuclear Instruments and Methods Research 214 (1983) 253. https://doi.org/10.1016/0167-5087(83)90591-4

4. Rosenfeld A. B., Pugach V. M., Zinets O. S. et al. Strip detector for short-range particles. Nuclear Instruments and Methods A 326 (1993) 234. https://doi.org/10.1016/0168-9002(93)90357-N

5. Rudge A. Comparison of charge collection in semiconductor detectors and timing resolution, using a sub-nanosecond transimpedance amplifier. Nuclear Instruments and Methods A 360 (1995) 169. https://doi.org/10.1016/0168-9002(95)00091-7

6. Литовченко П. Г., Розенфельд А. Б., Зинец О. С. и др. Субмикронная позиционная чувствительность полупроводниковых стрип-детекторов. Укр. фіз. журнал 35 (1990) 12.

7. Anokhin I. E., Zinets O. S. Distribution of electric field and charge collection in silicon strip detectors. Матеріали щорічної наукової конференції Інституту ядерних досліджень НАН України (1995) c. 161.